23/12/2024

OM3 96 Core SC Fibre Fan Out
Art.-No. 859-21737 | RNFTD96-SFSFM3-10.0M Details

  • No fibre terminations on site
  • Direct patching of equipment
  • Metal fan out unit with integral cable strain relief for both distribution cable and single elements
  • Simple neat patching solutions
  • Available in OM3, OM4, OS1 and OS2 in 12, 24, 48, 96 or 144 Core
  • Pre-tested with test results supplied
Show more

Request your individual offer now

Application The RapidNet fanout to fanout fibre cable is designed to support a wide range of applications including data centres, campus connectivity and disaster recovery sites. RapidNet from HellermannTyton is the unique, pre-terminated and pre-tested solution that offers uncompromised performance and quality. RapidNet fanout to fanout fibre cables are pre-terminated and pre-tested, installation times can be reduced by up to 95% and virtually eliminate the risk of dust and dirt affecting the connectivity and overall performance. RapidNet fanout to fanout fibre cables are available from 12-144 core options. RapidNet fibre fanout to fanout cables are available in straight through or cross over orientation available (For duplex links)
Colour Aquamarine (AE)
Connector Colour Beige (BGE)
Connector Type SC
Description The SC to SC Fibre Fan Out to fan out cable is pre-terminated offering high performance multimode patching at both ends. The SC Fan Out cable is a multi-core cable that has a smaller diameter than the equivalent number of fibre patch leads and therefore takes up less space in the trays and pathways. The fan out to fan out cable is designed to support a wide range of applications including data centres, campus connectivity and disaster recovery.
Local order number RNFTD96-SFSFM3-10.0M
PART DESCRIPTION RNFTD96-SFSFM3-10.0M
Pack Cont. 10.0m
Performance Category OM3 Multimode
Port count 96
Product Family Multimode SC to SC Fan Out
Product Group SC Fibre Fan Out Cables
Short Description OM3 96 Core SC Fibre Fan Out
Technical Description All adaptors are keyed so they connect in the correct orientation ensuring correct polarity for the link. The fan out unit includes integral strain relief and the furcation tubing on the individual fibres means that the breakout fibres can be used as a standard patch lead. NB. Part numbers shown are for 10m length, other lengths are available. The standard fan out breakout length is 0.5m for cable lengths between 2m to 5m and 1m for cable lengths over 5m.
Type RNFTD96-SFSFM3-10.0M
Length (L) 10.0m